Ultrabook, Celeron, Celeron Inside, Core Inside, Intel, Intel Logo, Intel Atom, Intel Atom Inside, Intel Core, Intel Inside, Intel Inside Logo, Intel vPro, Itanium, Itanium Inside, Pentium, Pentium Inside, vPro Inside, Xeon, Xeon Phi, Xeon Inside, and Intel Optane are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other countries.
Overview
SymmetraFeatures & Benefits
Manageability
-
SmartSlot
Customize UPS capabilities with management cards.
-
Network manageable
Provides remote power management of the UPS over the network.
-
Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
-
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
-
LCD display
Alpha-Numeric Display which displays system parameters and alarms.
-
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
Scalability
-
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
-
Scalable runtime
Allows additional run time to be quickly added as needed.
-
Programmable frequency
Ensures compatibility with different input frequencies.
-
Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.
-
Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
Protection
-
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
-
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
-
Generator compatible
Ensures clean, uninterrupted power to the loads in the event of an extended power outage
-
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
-
Resettable circuit breakers
Enables a quick recovery from overload events.
-
Cold-start capable
Provides temporary battery power when the utility power is out.
Spesifikasi
Output
-
Output power capacity
11.2 KWatts / 16.0 kVA
-
Max Configurable Power (Watts)
11.2 KWatts / 16.0 kVA
-
Nominal Output Voltage
230V
-
Output Voltage Note
Configurable for 220 : 230 or 240 nominal output voltage
-
Output Voltage Distortion
Less than 5% at full load
-
Output Frequency (sync to mains)
47 - 63 Hz
-
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
-
Other Output Voltages
220, 240
-
Load Crest Factor
up to 5 : 1
-
Topology
Double Conversion Online
-
Waveform type
Sine wave
-
Maximum Output Current
73
-
Output Connections
(1) Hard Wire 3-wire (H N + G) (Battery Backup)
-
Bypass
Internal Bypass (Automatic and Manual)
Input
-
Nominal Input Voltage
230V , 400V 3PH
-
Input frequency
45 - 65 Hz (auto sensing)
-
Input Connections
Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH + N + G)
-
Input voltage range for main operations
155 - 276, 290 - 480 (3:1)V
-
Input Total Harmonic Distortion
Less than 7% for full load
-
Other Input Voltages
220V, 240V, 380V, 415V
-
Input Power Factor at Full Load
0.98
Batteries & Runtime